著作: Inatsugi Mikiko/[田中 克哉]/[北畑 洋]/[野﨑 淳平]/[川人 伸次]/[大下 修造]/Minute distance obtained from pulmonary venous flow velocity using transesophageal pulsed Doppler echocardiography is related to cardiac output during cardiovascular surgery/[The Journal of Medical Investigation : JMI]
ヘルプを読む
「著作」(著作(著書,論文,レター,国際会議など))は,研究業績にかかる著作(著書,論文,レター,国際会議など)を登録するテーブルです. (この情報が属するテーブルの詳細な定義を見る)
- 項目名の部分にマウスカーソルを置いて少し待つと,項目の簡単な説明がツールチップ表示されます.
種別 | 必須 | 学術論文(審査論文) | |||
---|---|---|---|---|---|
言語 | 必須 | 英語 | |||
招待 | 推奨 | ||||
審査 | 推奨 | Peer Review | |||
カテゴリ | 推奨 | 研究 | |||
共著種別 | 推奨 | ||||
学究種別 | 推奨 | ||||
組織 | 推奨 |
|
|||
著者 | 必須 | ||||
題名 | 必須 |
(英) Minute distance obtained from pulmonary venous flow velocity using transesophageal pulsed Doppler echocardiography is related to cardiac output during cardiovascular surgery |
|||
副題 | 任意 | ||||
要約 | 任意 |
(英) We studied the relationship between minute distance calculated from pulmonary venous flow (PVF) velocity tracing and cardiac output (CO) measured with thermodilution method in patients undergoing cardiovascular surgery. In 32 patients undergoing cardiovascular surgery, simultaneous measurements of hemodynamics including CO and transesophageal pulsed Doppler signals of PVF velocity were performed before and after surgical repair. Minute distance was calculated as the product of the heart rate and the sum of time-velocity integrals of PVF. The minute distance after surgical intervention increased from 1121 +/- 347 cm x sec(-1) to 1764 +/- 538 cm x sec(-1) (p < 0.001; mean +/- SD), while CO increased after surgical intervention from 3.5 +/- 0.9 L x min(-1) to 5.3 +/- 1.1 L x min(-1). Simple linear regression analysis showed that minute distance was related with CO before and after surgical intervention (r = 0.81 and r = 0.76, respectively). The changes in minute distance were also related with those in CO (r = 0.80). The present study demonstrated that minute distance obtained from the pulsed Doppler tracings of PVF velocity was related with CO during cardiovascular surgery in adults. These results suggest that the changes in CO could be estimated from minute distance in pulmonary vein. |
|||
キーワード | 推奨 |
|
|||
発行所 | 推奨 | ||||
誌名 | 必須 |
The Journal of Medical Investigation : JMI([徳島大学.医学部])
(pISSN: 1343-1420, eISSN: 1349-6867)
|
|||
巻 | 必須 | 52 | |||
号 | 必須 | 3,4 | |||
頁 | 必須 | 178 185 | |||
都市 | 任意 | ||||
年月日 | 必須 | 2005年 8月 初日 | |||
URL | 任意 | ||||
DOI | 任意 | 10.2152/jmi.52.178 (→Scopusで検索) | |||
PMID | 任意 | 16167536 (→Scopusで検索) | |||
CRID | 任意 | ||||
WOS | 任意 | ||||
Scopus | 任意 | ||||
機関リポジトリ | 110775 | ||||
評価値 | 任意 | ||||
被引用数 | 任意 | ||||
指導教員 | 推奨 | ||||
備考 | 任意 |
|